fuel pump relay
fuel pump relay
Author
Discussion

SMITHY1963

Original Poster:

6 posts

181 months

Friday 16th September 2011
quotequote all
please can someone help? where can i buy a fuel pump relay for a 1988 tvr s1 2.8 v6?
thnx

toenail1

20 posts

185 months

Friday 16th September 2011
quotequote all
Try TVR Carparts or you can try this linkhttp://www.thetoolboxshop.com/0-723-13-durite-fuel-pump-relay-4345-p.asp. good luck Charlie

BobLeeSwagger

12 posts

198 months

Friday 16th September 2011
quotequote all
Did it just randomly blow? Because mine has done that... Twice! I don't know if it can't handle the current and is just melting. I too would quite like to know where i can get one or two.

SMITHY1963

Original Poster:

6 posts

181 months

Friday 16th September 2011
quotequote all
thanks for replies, iam hoping it solves another problem, car revs fairly freely whilst standing, as soon as you try to pull away it coughs splutters n dies

Barry S1

1,709 posts

218 months

Friday 16th September 2011
quotequote all
Hi
i have had them from non tvr parts but not the same get them from tvr car parts
a bit more expensive but they work check the contacts if they are not good it will
melt the rely

mikel003003

1,084 posts

195 months

Friday 16th September 2011
quotequote all
My s1 fuel pump relay is discoloured near the terminals and replacement is in order its just a ford one so ford dealership ?

mikel003003

1,084 posts

195 months

Friday 16th September 2011
quotequote all
My s1 fuel pump relay is discoloured near the terminals and replacement is in order its just a ford one so ford dealership ?

Barry S1

1,709 posts

218 months

Saturday 17th September 2011
quotequote all
that's what i thought until it melted going to the classic Le Man last year
i had 2 spares 1 worked for about 300 yards the other one got me home but made
lots of strange noises the pins look the same but something must be different
got 2 from tvr car parts when i got home all fine now and still got 1 spare
if you get a ford one i would test it before going on i long trip a French motorway
is not the best place to find they don't work

mikel003003

1,084 posts

195 months

Saturday 17th September 2011
quotequote all
Ok cheers

BobLeeSwagger

12 posts

198 months

Monday 19th September 2011
quotequote all
Barry S1 said:
Hi
check the contacts if they are not good it will
melt the rely
Will it be the female contact in the fusebox or the male ones on the relay? How do i check the ones in the fusebox? Stick something narrow in and scrape the surface a bit?

Barry S1

1,709 posts

218 months

Monday 19th September 2011
quotequote all
i found with mine that the wires were loose in the the block that the relay pushed
in to so when you push the relay in it pushed the wire out the back of the block and was not connecting properly
which made it get hot and melt the rely, if you can get to the back of it check this as you push it in i pushed the wire in from the back with a small screwdriver it worked on mine

Barry

GreenV8S

31,017 posts

313 months

Monday 19th September 2011
quotequote all
One of the problems with this type of contact is that if the terminal gets hot the contact relaxes and loses the clamping load. It looks fine but hasn't got anything like the original current carrying capacity. Inserting and removing relays can make the problem worse. There's no easy way to detect it because there's no practical way to feel the force required to insert an individual contact as you insert the relay, short of making up your own test tool and then trying each terminal separately. Pushing the contact out and re-tightening it helps a bit but doesn't seem like a complete fix, I suspect the metal itself is being softened/annealed and loses its springiness.