Cooling fans not working
Discussion
Hi.my cooling fans have stopped working.I have checked there’s power to connectors at otter switch. Connected a wire to the cable connections to make a circuit I believe the fans should now run but they don’t..Connections at fans is ok. So need new otter switch?. Just checking before I buy a new one. Thanks.
Hi. Cooling fans still not working.What I have tried already. Connect fans directly to a battery they work,There is 13.5 volts to wires at otter switch looped the wires together fans still don’t work.All fuses ok. Only thing not checked is relay if this is shot would it stop fans working even if there’s power to cables at otter switch. Don’t know what else to look for. Thanks.
I agree that the otter switch should switch the relay 'on' to energise the load side. You can check the relay easily enough - plenty of youtube tutorials.
You could fit a bridge wire over the relay load side to see if the fans kick in (assuming there is power there). If they do then you know that side of the system works and you can turn your attention to the otter switch side of the system.
You could fit a bridge wire over the relay load side to see if the fans kick in (assuming there is power there). If they do then you know that side of the system works and you can turn your attention to the otter switch side of the system.
DVR V8 said:
You shouldn't have 13.5 volts at the otter switch. It's a negative that operates the yellow relay top left. If the car is pre 1997 there will be another relay wired into the circuit hanging loose inside the fuse box.
Chimaera could be different but is it not live to relay coil, then onto Otter switch which provides the earth when it "makes"?phillpot said:
Chimaera could be different but is it not live to relay coil, then onto Otter switch which provides the earth when it "makes"?
Pretty sure it is.Can't remember the colours at the otter switch but one will be gound, possibly black in colour.
It's worth checking it is still attached to ground as shorting the otter will do nothing if it isn't.
Relay from memory is a basic 4 pin 30 amp so should be able to get one locally, 40 amp would be better if possible.
Edited by Belle427 on Thursday 29th June 07:30
All sorted . Changed 2relays and only 1 fan running, changed connectors on other fan both running now . Old connection seemed fine but when I stripped wires back copper wire was black. Trimmed them back put new connections on. Will replace cable when I get over this weekend.
Mine is a 96 but this is my fuse board. Thanks everyone for your advice.