Pneumatic compressor tripping

Pneumatic compressor tripping

Author
Discussion

Lupogti123

Original Poster:

8 posts

41 months

Saturday 9th November
quotequote all
Gents,

Can anyone help, I have tried to start up my single phase compressor though it keeps blowing the 13a fuse, not even trying to start.

I was in a pickle so I put some foil around the fuse and it fired up though it was slow to turn over, struggled a bit and then tripped the fuse board.

Anyone offer any advice? I replaced the capacitors a few months back but they were cheap off Amazon?

Motor is free to turn by hand?

Cheers,

Ed


normalbloke

7,711 posts

226 months

Saturday 9th November
quotequote all
Is the unloader valve working properly, cleaned and assembled correctly?

Lupogti123

Original Poster:

8 posts

41 months

Saturday 9th November
quotequote all
I will check in the morning but I opened the drain valve when trying to get it going to see if I could get the motor to speed up but didn’t help

I am alright Jack

3,848 posts

150 months

Saturday 9th November
quotequote all
Sounds like what normalbloke said or faulty capacitor.

Bessacarr

35 posts

126 months

Saturday 9th November
quotequote all
47 microfarad capacitor on side of motor. Change that.
At least see if it's a 47 but will be close to that

Lupogti123

Original Poster:

8 posts

41 months

Sunday 10th November
quotequote all
It’s a 25uf capacitor, I can get the motor to run under no load but as soon as I bolt the compressor back on it blows the fuse.

I have checked the valves etc all seems ok.

The compressor feels free to turn, going to order another capacitor and try again,

I am running off a 13a plug but it worked fine before I moved home?

Cheers,

Ed

paintman

7,765 posts

197 months

Sunday 10th November
quotequote all
If it worked fine before you moved it could be something as simple as the socket you're plugging it into is at the end of a long run or has a lot of things plugged into it or you're using a long thin extension cable & the voltage drop means there's not enough to kick the compressor over.
Met this from time to time when SMART repairing at people's houses.

iguana

7,055 posts

267 months

Monday 11th November
quotequote all
I had this, had worked for years same socket & extension cable, I'd put more lights on the same circuit & it kept being really sluggish to start, then just wouldn't start & kept blowing fuses.

Swapped to another plug socket with no other things on the circuit, problem fixed.