Generator 240v plug
Author
Discussion

GTIR

Original Poster:

24,741 posts

296 months

Tuesday 14th October 2008
quotequote all
Hi all, can the PH massive help me with this plug on my 2.3kva generator.

I cannot seem to find a plug to fit, the only 240v ones I can find are the three pin type.
It has an earth point to the right, you can just see it in the pic, but only two pin holes?


xllifts

3,724 posts

233 months

Tuesday 14th October 2008
quotequote all
GTIR said:
Hi all, can the PH massive help me with this plug on my 2.3kva generator.

I cannot seem to find a plug to fit, the only 240v ones I can find are the three pin type.
It has an earth point to the right, you can just see it in the pic, but only two pin holes?

That becuase its a french type socket
you can buy the plugs at any french hypermarket
HTH
Dave

mechsympathy

58,736 posts

285 months

Tuesday 14th October 2008
quotequote all
xllifts said:
That becuase its a french type socket
you can buy the plugs at any french hypermarket
HTH
Dave
heheIt's probably worth trying a caravan shop.

IanParker

391 posts

277 months

Tuesday 14th October 2008
quotequote all
Think it's a European socket on that.

Slikk

2,135 posts

273 months

Tuesday 14th October 2008
quotequote all
Connect the wires to a pair of scissors and put the pointy ends in the holes.


This is not to be taken seriously. It is an attempt at light hearted banter. If you consider the above to be an option, please step away from the generator and leave it well alone.

V8mate

45,899 posts

219 months

Tuesday 14th October 2008
quotequote all
GTIR said:
Hi all, can the PH massive help me with this bargain I picked up on eBay.

It went for an absolute song; couldn't believe how cheap I go it. Just can't seem to find a plug to fit

frown

EFA

GTIR

Original Poster:

24,741 posts

296 months

Tuesday 14th October 2008
quotequote all
V8mate said:
GTIR said:
Hi all, can the PH massive help me with this bargain I picked up on eBay.

It went for an absolute song; couldn't believe how cheap I go it. Just can't seem to find a plug to fit

frown

EFA
silly

elster

17,517 posts

240 months

Tuesday 14th October 2008
quotequote all
ebay link

Summat like this.

hugoagogo

23,437 posts

263 months

Tuesday 14th October 2008
quotequote all
it would work with most french things, but it's not really just a french one, cos they often have a pin poking out, and a matching female bit in the plug

i'd call it a german one, but usually in practice, plugs fit both

edit: if you want me to post you one over, gis a pm

just a bare plug that you could wire to an extension lead would only be 1 euro or less

edit again: the earth is the bit going 90° to the two pins

Edited by hugoagogo on Tuesday 14th October 16:22

GTIR

Original Poster:

24,741 posts

296 months

Tuesday 14th October 2008
quotequote all
elster said:
ebay link

Summat like this.
You are a legend sir. biggrin

jag guru

556 posts

228 months

Tuesday 14th October 2008
quotequote all
I would be inclined to replace the whole socket, for the UK 3pin
type........Try Screwfix " MK industrial commando ( seriously ) socket
K9233 32A -240V-BLU " £8.49 inc VAT. That would allow you to use the
corresponding 3 pin plug.
Not too involved to change this over, if you're reasonably hands on.


cjs

11,684 posts

281 months

Tuesday 14th October 2008
quotequote all
It is not French. It is a Shucko, mainly used in Germany and some other European countries. The French version has an earth pin.


http://cpc.farnell.com/CN06990/electrical-lighting...

Edited by cjs on Tuesday 14th October 18:26

cjs

11,684 posts

281 months

Tuesday 14th October 2008
quotequote all
jag guru said:
I would be inclined to replace the whole socket, for the UK 3pin
type........Try Screwfix " MK industrial commando ( seriously ) socket
K9233 32A -240V-BLU " £8.49 inc VAT. That would allow you to use the
corresponding 3 pin plug.
Not too involved to change this over, if you're reasonably hands on.

A 32 amp socket would allow overload to the generator, its only 2.3kv which is about 10 amps.

SVT Rick

3,633 posts

225 months

Tuesday 14th October 2008
quotequote all
Just wire a trailing lead into the top box off the back of the offending socket with a rubber 13amp socket on the end or replace it with a 16a Lewden / Commando type socket.

Take yer 15 mins tops


Ganglandboss

8,554 posts

233 months

Tuesday 14th October 2008
quotequote all
cjs said:
jag guru said:
I would be inclined to replace the whole socket, for the UK 3pin
type........Try Screwfix " MK industrial commando ( seriously ) socket
K9233 32A -240V-BLU " £8.49 inc VAT. That would allow you to use the
corresponding 3 pin plug.
Not too involved to change this over, if you're reasonably hands on.

A 32 amp socket would allow overload to the generator, its only 2.3kv which is about 10 amps.
No it wouldn't, the load you connect to it would. Although a 16A socket would be more appropriate, the generator is potected by a circuit breaker to prevent overload.

MonkeyHanger

9,267 posts

272 months

Tuesday 14th October 2008
quotequote all
Ganglandboss said:
No it wouldn't, the load you connect to it would. Although a 16A socket would be more appropriate, the generator is potected by a circuit breaker to prevent overload.
And there i was trying to come up with a polite way of pointing out the error in his post wink

jag guru

556 posts

228 months

Wednesday 15th October 2008
quotequote all
Ganglandboss said:
cjs said:
jag guru said:
I would be inclined to replace the whole socket, for the UK 3pin
type........Try Screwfix " MK industrial commando ( seriously ) socket
K9233 32A -240V-BLU " £8.49 inc VAT. That would allow you to use the
corresponding 3 pin plug.
Not too involved to change this over, if you're reasonably hands on.

A 32 amp socket would allow overload to the generator, its only 2.3kv which is about 10 amps.
No it wouldn't, the load you connect to it would. Although a 16A socket would be more appropriate, the generator is potected by a circuit breaker to prevent overload.
Er.......believe it or not, I'm an electrical engineer. 32A is THE MAX CURRENT the socket is capable of
handling, not what the generator can supply.
So, OK use a 16A as Ganglandboss suggested. I listed this one as it was
the first IP44 240V socket I came to.

Yes, you are quite correct CJS, the max gen O/P is 10A ( I=P/V )
I humbly apologise for the ambiguous post !


Edited by jag guru on Wednesday 15th October 01:18

jag guru

556 posts

228 months

Wednesday 15th October 2008
quotequote all
K9201 16A/240V SOCKET. £5.49.Cat No 40962.
K9001 16A/240V PLUG . £2.59.Cat No 97317.

From Screwfix.

Both cheaper than the 32A equivalents ! And the cheapest I
can find...........unless someone know better !

Ganglandboss

8,554 posts

233 months

Wednesday 15th October 2008
quotequote all
To add to what myself and jag guru have said, the rating of any accessory or cable must be equal to or greater than the rating of the protective device, not the other way round.

jag guru

556 posts

228 months

Wednesday 15th October 2008
quotequote all
Ganglandboss said:
To add to what myself and jag guru have said, the rating of any accessory or cable must be equal to or greater than the rating of the protective device, not the other way round.


Ganglandboss is 100 % correct, as always.....Cheers Dave.

Edited by jag guru on Wednesday 15th October 03:12